Simply Stabilizing the Loop via Fully Looped Transformer
Authors: Rao Fu, Zixuan Yang, Jiankun Zhang et al.
Summary
arXiv:2605. 18797v1 Announce Type: new Abstract: Scaling model performance typically requires increasing model size.
Relevance
Read next because Simply Stabilizing the Loop via Fully Looped Transformer overlaps with clean result "LoRA persona trained on alone emits at 23.5% when a co-trained partner learns ..., vs 0% control on Qwen2.5-7B-Instruct (MODERATE confidence)", clean result "Leakage rate is a usable signal for recovering trigger-shaped phrases on Gaperon-1125-1B without knowing the hidden trigger itself (MODERATE confidence)", clean result "Language-mismatch LoRA SFT on Qwen2.5-7B leaks the trained completion language into bystander directives the model was never trained on, absent under same-language SFT (LOW confidence)". Matching terms: text, under, source, line, rate, without, does, full. Source: arxiv cs.LG (Machine Learning).
Abstract
arXiv:2605.18797v1 Announce Type: new Abstract: Scaling model performance typically requires increasing model size. Looped Transformer offers a compelling alternative by iteratively reusing the same Transformer blocks, trading additional computation for improved performance without increasing parameter count or context length. Because the number of loop iterations can be adjusted at inference, it also provides a natural mechanism for balancing performance and test-time compute. However, Looped Transformer still suffers from training instability when the number of loop iterations increases. Our analysis reveals that this instability stems from two sources: gradient oscillation and residual explosion. To address these two problems, we propose the Fully Looped Transformer, which introduces two parameter-free modifications: (1) Fully Looped Architecture, which distributes inter-loop signals across all layers to mitigate residual explosion; (2) Attention Injection, which reuses the existing attention block to suppress gradient oscillation. These modifications stabilize training dynamics, enabling the Fully Looped Transformer to be trained stably up to 12 loop iterations, whereas other baseline looped models collapse in this regime. In milder settings where Looped Transformer does not collapse, Fully Looped Transformer still improves average downstream-task performance by up to 13.2%. Overall, our experiments demonstrate that Fully Looped Transformer improves training stability, enhances downstream performance, and provides preliminary adaptability under different test-time compute budgets by varying loop iterations at inference.